File size: 3715 kB Views: 4474 Downloads: 27 Download links: Mirror link
This large scale regeneration project in Birmingham required IGs bow lintels, for the final phase of 355 apartments to achieve the seamless brickwork.IGs lintel selector helps you to find the right lintel to suit your project at the click of a button. Wondering which lintel do I need – this is for you.Discover our wide range of steel lintels, use our lintel selector to find the. IG Lintels supports architects and designers, pushing the possibilities of.Our guide shows you step by step how to choose the right lintel for your project. timer frame lintel - selecting the correct lintel with IG Lintels.All IG standard lintels. IGs full range of lintels is also available in. SIZES. ARCH SPAN. RISE. REFERENCE. The Cant brick Lintel can be supplied to.Lintel Selector - Choosing the Correct LintelSelecting the Correct Lintel - What lintel do I need?PRODUCT GUIDE - IG Lintels
Hi-therm+ Lintels - The low cost solution to reduced CO2 emissions and improved Fabric Energy Efficiency, helping to achieve Part L Building Regulations.L9. To achieve loading figures lintel must be built in as shown. Lintels may be propped to facilitate speed of construction. Get a Quote.Timber Frame Lintel. Provide Keystone steel lintels manufactured and designed in accordance with BS EN 845-2:2003. Keystone Lintels,Avondale Road, Cwmbran.IG has a range of over 800 lintel types, varying from cavity wall lintels, single leaf,. They are available in 3 sizes and supplied in flat packs.Single Leaf Lintels (L8). IGs range of Single Leaf Lintels are available to support standard loads and heavy duty loads. To achieve loading figures steel.Heavy Duty Load Steel LintelsSteel Lintel Solutions Wide Range of Standard and Special.Product Specification - IG Lintels. juhD453gf
The inner leaf is supported through a standard Keystone Box lintel with factory fitted lateral restraint clips. The outer leaf support comes from the uniquely.L1/XHD 150: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.A big thanks to everyone who came along and had a go at our lintel modelling challenge, who knew there were so many hidden artists among their staff and.100mm inner leaf lintel – use our handy lintel selector tool to find the perfect lintel for your needs or if you need help contact our expert team.L1/HD 75: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.To achieve loading figures lintel must be built in with blockwork as shown. Ensure all perpendicular and horizontal joints are filled with mortar.L1/S 110: For Cavity widths 110-125mm ; 600 1500, 97, 2.0 ; 1650 1800, 113, 2.0 ; 1950 2100, 125, 2.0 ; 2250 2700, 163, 2.5 ; 2850 3000, 193, 2.9.L1/XHD 110: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.The latest news stories, updates, event and competitions from IG Lintels, stay up to date with the latest innovations in the construction industry.HDBOX 100: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.Browse IGs extensive range of standard load lintels or use our lintel selector to instantly find which type of lintel you need.IGs Special Lintel range, helps architects to design more creatively, thanks to their innovation and adaptability. From Gothic Arches to Parabolic Arches,.For IG Lintels twin engineers Mark and David Hutchings, the workplace is neutral ground for sharing advice. The golf course is where the competitive magic.L6/75: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.L5/150: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.Steel Lintels may be propped to facilitate speed of construction. Inner leaf block should not overheat the lintel flange by more than 25mm.To achieve loading figures the lintel must be laterally restrained. Maximum overhang of 30mm on outer leaf. Steel Lintels may be propped to facilitate speed.Special Lintels. IG Lintels supports both architects and designers, pushing the boundaries and possibilities in steel lintel design with our custom,.HDBOX 140: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.The flange of the HD BOX/K-200 is designed to support a nominal masonry load only up to a maximum of 3kN per metre run. Used to support openings in 215mm wide.L1/HD 110: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.Standard IG Lintel. All IG standard steel lintels satisfy the Thermal Performance requirements of England and Waless Part L of the building regulations,.IG has a nationwide network of sales professionals with expert knowledge of both technical and commercial aspects of the steel lintel industry. Your IG Regional.L7/50: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.HT/XHD+ 100 – For cavity widths 90-105mm ; 600 – 1500, 234, 2.9/3.2, 40 ; 1650 – 2400, 218, 2.9/2.5, 48.The lintel selector tool helps visitors to find the correct lintel for their specific needs at the click of a button while a helpful video.IGs brand new Brick Slip Feature Lintels brochure details the wide range of custom made solutions available to architects and house builders,.The L7 timber frame lintels must be used in conjunction with lateral restraint clips and a tight fitting timber batten, as shown, to prevent twisting.Contact us – telephone numbers, locations, addresses and email contacts for IG Lintels in Swadlincote, Derbyshire and Cwmbran, Wales.IG Lintels. About us. Lintel Selector · Selecting Correct Lintel · Psi Value Calculator. At IG Lintels were celebrating National Engineers Week,.IG Lintels. About us. Lintel Selector · Selecting Correct Lintel · Psi Value Calculator. IGs Josh Morris and John Pilapil had a great time at the.I BEAM TJ: For Cavity widths 200-300mm ; 600 1800, 227, 2.5 ; 1950 2100, 227, 2.5 ; 2250 3000, 227, 2.9.L1/HD 50: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.L1/XHD 50: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.L7/75: For installation advice please refer to our lintel installation guide. For more guidance please contact our technical team.L5/50 WIL: For Cavity widths 50-65mm ; 600 1500, 229, 2.9 ; 1650 2100, 229, 2.9 ; 2250 3000, 229, 2.9.